Whether you test monthly, twice a year, or once a year depends upon the type, location, and importance of the equipment. The following sections of the ansineta standard for acceptance testing specifications for. For over 100 years the ducter test has been used to describe a simple test for measuring very low contact resistances and ducter, which is still used as a trade mark, was the name originally given to the low resistance ohmmeter manufactured by megger. This has practical applications for testing contact resistance in switches, bonds and circuit breakers. Switchgear testing and commissioning procedure electrical. The megger ducter dlro10 and ducter dlro10x bring new standards to low resistance measurement. The aemc 10a microohmmeter, or ductor tester model 6240 is a rugged, low resistance tester designed for both plant maintenance and field use. Can any body tell me what are the acceptable code values for contact resistance bus ductor test to bus sections, bus bars etc thank you. Due to the number of employment enquiries received we do not reply to. Typically, primary fuses deal with a high current carrying load. Ductor is a global biotech company that is changing the world through groundbreaking innovation, design, and the circular economy. While doing the hv test the steps to be followed are as below. The ductor test is a simple test used in very low scale resistance measurement. Ductor test digital ductors for use in measuring low resistance.
These can be connections between any two conductors, for instance busbar sections or cable connections. A dc milliohm resistance measuring test, normally used to measure circuitbreaker and tapchanger contact resistance. The simple purpose of the fuse is to accurately limit current flow throughout the secondary distribution system. The megger dlro duplex connect four terminal test lead system is designed to provide the most cost effective and convenient way to provide the user with all off the test lead terminations and lead lengths required for the many different applications encountered in low resistance testing. Lv panel testing procedure in new 2017lv switchgear. The instrument which is used to perform the ductor test is called an ohmmeter, and since its function is to perform the ductor test, the ohmmeter is also known as a ductor tester. Section 7 of the ansineta standard for acceptance testing specifications for electrical power equipment and systems may be reproduced and used on a cut and paste basis for the particular type of equipment to be tested. Discover how to test a circuit breaker with the different test sets that you can need.
Testing and commissioning procedure for electrical installation 1. The 6240 ductor tester utilises a fourlead kelvin method of testing, the model 6240 microohmmeter accurately measures very low resistance to within 0. Measurement of winding resistance and insulation resistance of 3 phase 11 kv 433 v, 16kva oil cooled type transformer. Oct 09, 2019 the combination, with a fountainroller and an inkcylinder, of a ductor movable between said roller and cylinder for delivering ink from one to the other. Megger dlro10hd digital microhmmeter inlec test equipment. Get help and answers to any engineering problem including electrical, electronics, mechanical, telecommunication, instrumentation, computer, mathematics, physics etc. Jun 28, 2017 how to perform insulation resistance megger test instrumentation abc. After the test current has been set, the automatic test procedure is started by pressing the obutton.
Dlro10x also adds realtime download of results and onboard storage for later download to a pc. Supplied complete with 5m test leads and download software. The dlro10 is built into a strong, lightweight case that is equally at home in the field or in the laboratory. Megger dlro10 digital low resistance ohmmeter tequipment. How to test an inductor learning about electronics.
Ductor definition of ductor by the free dictionary. The contact resistance was often applied in quality testing of switches, relays and pcb pads and testing of the shield assembly for emc. Standard for acceptance testing specifications for electrical. The test is carried out by injecting a high current and measuring the voltage across the device. Fill in the voucher and send to the address shown, along with a fluke distributors invoice to claim a free. Welcome to, where students and teachers can ask and answer any question. The complete guide to electrical insulation testing. High voltage test is done by applying 80% of factorytested voltage. What is the difference between a megger and a ductor.
Once the test button is depressed the test lamp will illuminate and the instrument will undertake a single test to verify the resistance of the test object. Ductor test digital ductors for use in measuring low. We stock a range of ductor testing equipment suitable for testing switchboards, welded joints, railways and other applications. Measurement of winding resistance and insulation resistance. Both are fully automatic instruments, selecting the most suitable test current, up to 10 a dc to measure resistance from 0. Megger dlro100xb portable datalogging 100 amp digital low. The method of measuring contact resistance has been summed up in this article, and the factors that induce measurement uncertainty have been discussed. Using the dvwin software a test can be performed from a users pc, and the results can be obtained directly on the pc. The megger dlro10 bring new standards to low resistance measurement.
The instrument will continue to test, updating the display after each new test cycle, until the test button is pressed or the test procedure times out. Contact resistance test is commonly known as ductor test. Megger test is an electric test used for measuring insulation properties in electrical power applications while contact resistance test measures the resistance of electrical connections. Standard for acceptance testing specifications for. For example, a small pump motor or a short control cable may be vital to a process in your plant. Ink is transferred to the ink distribution rollers by a ductor roller. These conditions result in a decrease in the surfacetosurface contact area with an associated increase in surfacetosurface contact resistance, ultimately causing excessive heating at the junction. The autoohm200 s3 is vanguards fourth generation, microprocessorbased, true dc microohmmeter. This program is used to interface with the m4500 of the hslductor, allowing the user to view and modify setup data, view production data, download the application program to the package, as well as download and upload setup data to the package. By taking the inductors resistance, we can determine whether the inductor is good or bad. The megger dlro10 nls ducter ohmmeter brings new standards to low resistance measurement.
The following is a link to the windows based setup program for the hslductor. The contact resistance of busbar joints will depend on the type of joint bolted, clamped, welded, etc, contact area and pressure, and this will obviously differ across manufacturers. Ductor synonyms, ductor pronunciation, ductor translation, english dictionary definition of ductor. The test measures the resistance at the micro or milliohm level and is used. I have only done this once, but the basic procedure was fairly simple. It isnt as fast as it could be, and more importantly id like opinions on whether it will work as intended.
Also known as ductors, micro ohmmeters work by injecting very high test currents up to 600a through a conductor in order to measure extremely low resistances with excellent accuracy and resolution. Dec 15, 2011 megger dlro10 digital low resistance ohmmeter. Thanks lads, im still in the dark to what manufacturer of the busbar is etc as im not there to see it yet but its brand new solid copper rising busbar, and yes not sure what ductor tester they will be supplying me so will have to see on that one, but wasnt sure if there was a general procedure ie testing between cores or linking them all out. Aug 24, 20 the contact resistance test commonly known as the ductor test measures the resistance of electrical connections such as joints, terminations, connectors, etc. Ive breadboarded a circuit that is basically working but could use a tuneup. What is megger test and how is it performed the device is being used since 1889, popularity raised during 1920s, since long back devise is same in its uses and purpose of testing, few real improvement appeared in recent years with its design and quality of tester. How to perform insulation resistance megger test instrumentation abc.
Im not sure there is a code for ductor tests on busbars perhaps ansineta ats, but ive never used it. A fully automatic instrument, selecting the most suitable test current, up to 10 a dc to measure resistance from 0. A ductor tester, or microohmmeter is capable of measuring the lowest resistances. Megger dlro200 low resistance micro ohm meter dlro 200. The best test to check whether an inductor is good or not is by testing the inductors resistance with your multimeter set to the ohmmeter setting. Due to the number of employment enquiries received we do not reply to emails and we do not deal with agencies.
The megger ducter dlro10x bring new standards to low resistance measurement. Megger dlro100e digital low resistance ohmmeter ac operated. Micro ohmmeters ductors test meter electrical test. Megger dlro100e digital low resistance ohmmeter ac.
Dlro 10x uses a menu system controlled by a twoaxis paddle to allow manual selection of the test current. The dlro10 digital microhmeter is a lightweight robust instrument which is equally at home in the field or in the laboratory. This will define how to test a circuit breaker through different testing tools to be applied to check the equipment under a range of conditions or operation types. Testing and commissioning procedure for emergency generator installation 1. The fluke 1654b installation tester must be purchased with the fluke 411d on the same order between 1st september 2011 and 31st december 2011. Ask for procedure of ductor test cr4 discussion thread.
The contact resistance test commonly known as the ductor test measures the resistance of electrical connections such as joints, terminations, connectors, etc. We do this by taking the probes of the multimeter and placing them across the leads of the inductor. Megger dlro10x 10 a low resistance ohmmeter with test. The megger dlro200 microhmeter measures resistances between 0. How to perform insulation resistance megger test youtube. Introduction the procedures stated in this document cover the activities in preliminary tests and inspections, functional performance tests and the commissioning of newly completed installations and existing ones after major alteration. For over 100 years the ducter test has been used to describe a simple test for measuring very low contact resistances and ducter, which is still used as a trade mark, was the name originally given to the low resistance ohmmeter. It is a fully automatic instrument, selecting the most suitable test current, up to 10 a dc to measure resistance from 0. Inspection, test and measurement procedures for lv and mv up to 36kv switchgears on photo eaton cutler hammer magnum ds switchgear inspection, and transformer testing for mv switchgear similar considerations apply although more extensive checks on protective devices, circuit breaker oil, vacuum bottle contact distances are required as. Our ambition is to fight climate change, produce renewable energy, and solve the increasing food demand and waste accumulations challenges. It is designed for testing ehv circuitbreaker contact resistances, bushing contact joints, welding joints, or for any lowresistance measuring application. A new method of indirect measuring contact resistance has. Megger dlro10 digital low resistance ohmmeter youtube.
Ductor measures conductance which is very low resistance. View and download megger dlro10 user manual online. The rmo200g instrument can store internally up to 500 measurements. For a moment i thought it is a new kind of test im not familiar with. The two positive and negative high amperage dc leads, and two smaller also positive and negative leads. White paper the benefits of plm built on the salesforce platform.
1505 100 1506 789 1608 194 1381 1209 664 735 1263 832 320 208 989 1030 1494 1481 1378 1187 659 269 9 1563 1340 1498 221 109 1492 1270 666 784 1264 904 1414